CONDENSING GAS + PUMP
NPE-A2
Pump and buffer tank inside.
Three models from 8.4 to 11.2 GPM, each rated 0.95 UEF and ENERGY STAR certified. ComfortFlow recirculates through a return line or, with the optional NaviCirc valve, your existing pipes.
Navien’s NPE-A2 puts a recirculation pump and buffer tank inside a condensing gas heater rated 0.95 UEF. We’ll size yours and plan the return line or NaviCirc valve the pump needs.

NPE-A2 and NHW-A have ComfortFlow built in; NPE-S2 and NHW-SU work with an added pump. Condensing models rate up to 0.96 UEF, non-condensing 0.81.
CONDENSING GAS + PUMP
Three models from 8.4 to 11.2 GPM, each rated 0.95 UEF and ENERGY STAR certified. ComfortFlow recirculates through a return line or, with the optional NaviCirc valve, your existing pipes.
CONDENSING GAS
Four models from 6.8 to 11.2 GPM with the NPE-A2’s dual stainless steel heat exchangers. Three are rated 0.96 UEF and the NPE-150S2 0.93. Recirculation needs an external pump.
NON-CONDENSING GAS + PUMP
Navien’s first non-condensing series with ComfortFlow, in 160,000 to 199,900 BTU/h sizes rated 0.81 UEF. Choose NHW-AI indoors or NHW-AE outdoors; one of the 5 recirculation modes uses the optional HotButton.
Flow figures are Navien’s maximums at a 35°F rise and fall as the rise grows. Each model has its own ratings, and your quote names the one that applies.
Navien, Inc. has operated in North America since 2006 and is headquartered in Irvine, California. Its parent company, KD Navien, is based in Seoul, South Korea. It was founded in 1978 and says it built Asia’s first condensing boiler in 1988. Navien sells through professional contractors and says its tankless water heaters must be purchased and installed by a licensed plumber. Citing BRG Building Solutions, Navien says it was the top-selling brand of gas tankless water heaters in North America in 2023, condensing and non-condensing combined.
ComfortFlow is Navien’s patented system: a buffer tank, a recirculation pump and the controls that run them, built into the heater. Navien introduced it on the NPE-A in 2012 and says it was the first to put all three inside a tankless water heater. Its stated targets are the cold-water sandwich, a burst of cold water between two hot draws, and problems at minimal flow rates. It now comes built into two families: the condensing NPE-A2 and the non-condensing NHW-A, which began shipping in October 2023.
A pump inside the heater still needs a loop to push water through. If your home has a dedicated return line, ComfortFlow uses it. If not, Navien’s optional NaviCirc valve turns the cold supply line into the return. Navien recommends fitting it under the farthest accessible fixture from the heater. It stops circulation at about 95°F and is for indoor, horizontal installation only.
Start with flow and the temperature rise behind it: the gap between the water coming in and the temperature you set. Navien’s headline flow figures assume a 35°F rise. Houston’s incoming water averages about 67°F, though the seasons shift it, so that rise brings it to only about 102°F, and any hotter setting means a bigger rise and less flow. On the NPE-240A2, 11.2 GPM at a 35°F rise becomes 8.7 GPM at 45°F. We count the fixtures your household runs together, then pick the Navien that keeps up at the rise you actually need.
Next, condensing or not. The NPE-A2 and NPE-S2 share Navien’s NPE-2 condensing platform, launched in 2021, with dual stainless steel heat exchangers. They are rated 0.93 to 0.96 UEF and vent through PVC, CPVC, polypropylene or stainless steel, and their acidic condensate needs a drain. The non-condensing NHW-A and NHW-SU are rated 0.81 UEF and up to 9.5 GPM. Installed indoors, they need 3 by 5-inch metal concentric venting. Navien says non-condensing models usually cost less than comparable condensing ones.
Last, the pump. If your far bathroom waits a long time for hot water, an NPE-A2 or NHW-A brings ComfortFlow with it. If you would rather skip recirculation, or add a separate pump, an NPE-S2 or NHW-SU keeps the heater simpler.
Navien covers residential NPE-A2, NPE-S2, NHW-A and NHW-SU heat exchangers for 15 years, parts for 5 and labor for 1, in standard use or when the heater or an external aquastat controls the pump. An external pump set to circulate continuously through the heater counts as uncontrolled, and the terms shrink to 5 years for the heat exchanger, 3 for parts and 1 for labor. Coverage runs from the date of installation, and labor is paid as an allowance on Navien’s own schedule.
Those terms come with conditions. Navien says buying a heater online or through other e-commerce channels voids its warranty, and it requires installation by a properly licensed plumber or contractor. Freeze damage, scale build-up and missed maintenance are excluded. For a claim, start with your original installer; Navien says you are free to choose any licensed professional, who inspects the heater and reports to Navien’s technical support. Register the heater as well: Navien’s technical support can’t send parts for an unregistered product, and registering a PeakFlow A, PeakFlow C or WEC600 installed inline after October 10, 2024 adds one more year of labor coverage.
Gas comes first. The NPE-240A2 has a 3/4-inch inlet, and Navien says a 1/2-inch line can still work, up to 24 feet on the NPE-A2, if it is sized to the National Fuel Gas Code tables. In 2-inch pipe the vent can run up to 75 feet with at most 6 elbows; in 3-inch pipe, up to 150 feet with at most 8. It can’t be shared with another appliance or run through a chimney. Condensate leaves at a pH of 3 to 5 and drains to a floor drain, laundry tub or utility sink, through a neutralizer where local code requires one. Power is 120 volts, at up to 2 amps or 4 with an external pump, and Navien says no dedicated electrical line is needed.
A Navien install needs a plumbing permit, pulled in Texas by a licensed master plumber acting as the Responsible Master Plumber and, in Houston, registered with the City; our permit guide covers the process. Our published $4,200 to $8,000 tankless range covers equipment and installation, and our tankless installation page breaks down what raises or lowers a quote. Trading an old tankless for a new Navien typically takes 4 to 6 hours; our tankless venting guide covers the pipe work.
Navien recommends descaling at least once a year, and more often the more minerals your water carries. The USGS classes Houston’s water, at about 8 grains per gallon, as hard. In Navien’s descaling guide, a cleaning solution circulates for at least 45 minutes, then fresh water flushes the heater for at least 10, and Navien recommends hiring a professional for it. Its maintenance guide also covers the cold water inlet screen, a second screen on the NPE-A2’s recirculation inlet, the air intake screens and the condensate trap.
We handle that yearly descale for a flat $195: our tankless maintenance visit flushes the heater, runs a 12-point check and leaves you a written report. To slow scale between visits, Navien sells PeakFlow scale prevention systems, and we install whole-house filtration and softening. Whether a Navien displays an error code or runs cold, our tankless repair technicians track down the cause first, and most tankless repairs land in the $150 to $600 range.
Hot Water Guys installs, repairs and maintains Navien tankless water heaters across Greater Houston. Besides the gas line, vent route and condensate drain, a ComfortFlow plan settles how water gets back to the heater: a return line or a NaviCirc valve.
Navien rates flow at a 35°F rise, and every model delivers less as the rise grows. We count the showers and appliances you run at once.
The NPE-240A2 has a 3/4-inch gas inlet, and Navien allows a 1/2-inch line if it is sized correctly. It runs on 120 volts and draws up to 2 amps.
NPE-A2 models vent through plastic or stainless steel pipe, up to 75 feet in 2-inch pipe. Their acidic condensate, pH 3 to 5, needs a drain.
ComfortFlow needs a return line or the optional NaviCirc valve, which uses your cold supply line. Wi-Fi control needs an add-on NaviLink module.
Outdoors, the NPE-240A2 needs Navien’s Outdoor Vent Kit, and Navien recommends outdoor mounting only in mild climates. Freeze protection needs power and doesn’t protect the pipes leading in, and the warranty excludes freeze damage.
Navien says its tankless heaters can last up to 20 years with proper maintenance, and that hard water may call for it more often.
Navien recommends hiring a professional to descale, and warns that damaging the heater during routine maintenance may void the warranty.
Every Navien has a water screen on its cold inlet, and NPE-A2 models add one on the recirculation inlet. If performance changes, note any error code before you call.
Residential NPE-A2, NPE-S2, NHW-A and NHW-SU: heat exchanger 15 years, parts 5, labor 1. That holds for standard installs and for pumps run by the heater or an aquastat.
An external pump circulating continuously cuts that to 5, 3 and 1 years. Navien voids coverage on heaters bought online, and claims start with your installer or another licensed pro.
ComfortFlow, sizing, propane, controls, descaling, cost and how recirculation affects the warranty.
Both are condensing gas heaters on Navien’s NPE-2 platform. The NPE-A2 adds ComfortFlow, a built-in pump and buffer tank, and is rated 0.95 UEF; the NPE-S2 has no pump, and three of its four models are rated 0.96 UEF. Choose the A2 if you want recirculation without adding a pump.
Navien rates NPE-A2 models at 8.4 to 11.2 GPM and NPE-S2 models at 6.8 to 11.2 GPM, all at a 35°F temperature rise. With Houston’s incoming water at about 67°F, that rise heats water to about 102°F, and a hotter setting cuts the flow: the NPE-240A2 falls from 11.2 to 8.7 GPM at a 45°F rise. We size for the fixtures you run together at the temperature you want.
Every Navien tankless family is available for natural gas or propane, and NPE-2 models can be field converted from natural gas to propane by a qualified service agency. An NPE-2 can mount outside with Navien’s Outdoor Vent Kit, though Navien advises outdoor installs only in mild climates. The NHW-SU needs its vent cap kit outdoors, and the NHW-AE is the outdoor version of the NHW-A.
The NPE-A2’s control panel supports HotButton, an optional kit that runs recirculation on demand, and NHW-A models offer 5 recirculation modes, including Always On, Intelligent Preheat and Scheduled. Wi-Fi control needs an add-on module: NaviLink, or NaviLink Lite for a single unit.
Navien’s minimum is once a year, with more frequent descaling as mineral content rises. Houston’s water, about 8 grains per gallon, sits in the USGS hard range, so a professional descale belongs on your calendar every year. Navien says missed maintenance may void its warranty.
Our published tankless range, $4,200 to $8,000, covers the heater and its installation together. Within it, a Navien quote moves with the model, gas line, venting, condensate drain, recirculation setup and any code work. The range is not a price for any one model, so call us for a free quote.
It can. Navien’s residential terms of 15, 5 and 1 years on the heat exchanger, parts and labor hold as long as any recirculation is controlled by the heater itself or an external aquastat. An external pump left to run continuously drops them to 5, 3 and 1 years. Heaters bought online are not covered.
Describe your current water heater and whether your plumbing has a return line. We’ll suggest a Navien and plan the recirculation to match.